GDT internal hexagon click attachment aligned above the implant platform, illustrating the implant–abutment connection interface.

Click Attachment

GDT internal hexagon click attachment aligned above the implant platform, illustrating the implant–abutment connection interface.

GDT Click Attachments provide a trusted and effective solution for securing partial and full overdentures in edentulous cases. They provide a stable connection between dentures and dental implants through a silicone cap system, minimizing micro-movements and maintaining a tight marginal seal. Available in straight, 18°, and 30° angulations, they help correct implant divergences of up to 60°, supporting precise parallelism and long-term prosthetic success.

  • Connections
    • Internal Hexagon 2.42mm
      Internal Hexagon 2.42mm
    • Slim Internal Hexagon 2.0mm
      Slim Internal Hexagon 2.0mm
  • Material
    Titanium Grade 5 (Ti-6Al-4V Eli)
  • Torque Tightening
    20 Ncm For Components (Recommendation)

GDT Click attachments offer a solution for securing partial and full-arch restorations with exceptional ease, stability, and patient satisfaction. Our click attachments provide a highly retentive, durable, and aesthetic connection between the dental implant and the denture.

Click attachments are widely utilized in dental practices, forming an integral part of restoring edentulous and partially edentulous cases. Engineered for overdentures, GDT Click attachments are inserted directly into the dental implant and connected securely through a silicone caps system. This connection system minimizes micro-movements and delivers an exceptionally tight marginal seal, improving the prosthetic stability and the patient’s overall comfort.

Precision, Strength, and Comfort

All GDT Click attachments are manufactured from Titanium Grade 5 (Ti-6Al-4V ELI), a medical-grade alloy known for its strength, biocompatibility, and superior resistance to corrosion. This material selection ensures seamless integration with the dental implant, supporting long-term clinical success while maximizing patient safety.

One of the features of our Click attachments is the ease of use for dental professionals combined with simplicity in patient maintenance. Patients can easily care for their overdentures at home without complicated interventions, while dentists benefit from a reliable system that supports the longevity of the prosthesis and reduces chair time for adjustments.

Silicone Caps for Customized Retention

We provide a full range of silicone caps engineered for controlled retention forces. Our silicone caps are available in Extra Soft (0.6 kg/1.3 lbs), Soft (1.2 kg/2.6 lbs), Standard (1.8 kg/4.0 lbs), Strong (2.5 kg/5.5 lbs), and Lab silicone cap with no retention. This flexibility allows dentists to adapt the retention force precisely to the clinical case and the patient’s needs, ensuring superior comfort and functionality over time.

GDT Click titanium housing and silicone caps feature an extended service lifespan compared to other systems on the market, thanks to their natural, steady placement. This increased durability means fewer replacements and less maintenance.

Advanced Solutions with Angulated Click Attachments

GDT Angulated Click attachments are engineered for challenging clinical procedures. Offer an effective solution for overcoming implant divergence. Available with 18° and 30° angulations, these attachments can correct up to 60° of divergence in all directions, enabling perfect parallelism.

Platform Compatibility and Versatility

GDT Straight Click attachments are available with internal hex 2.42mm and slim platform internal hex 2.0mm connections. Our Angulated Click attachments are available in an internal hex 2.42mm connection, making them compatible with a wide range of leading dental implant systems. This ensures that our Click attachments can easily integrate into different treatment workflows.

GDT Click Attachment Sizes

L / TypeStraight – SlimStraight18˚30˚
0.5mm————LOC-1805LOC-3005
1mmLOC1-SLLOC1LOC-1810LOC-3010
2mmLOC2-SLLOC2LOC-1820LOC-3020
3mmLOC3-SLLOC3LOC-1830LOC-3030
4mmLOC4-SLLOC4————
5mm——LOC5————
6mm——LOC6————

TypeExtra Soft CapSoft CapStandard CapStrong CapLab Silicone CapProtective DiscTitanium HousingAnalogImpression CopingDriver
CodeSYCLSPCLSWCLSTCLSBCLDPMTCLAFLTFLHLC
Components
Straight Click Attachments
Straight Click Attachments
https://gdentalt.com/wp-content/uploads/2025/04/Standard-Platform-Internal-Hex-2.42mm-sign-with-dimensions.svg

Straight Click Attachments

LENGTH
1mm
2mm
3mm
4mm
5mm
6mm
 
GDT internal hex Click Attachment, 1mm collar height, gold anodized finish with threaded screw
GDT internal hex Click Attachment, 2mm collar height, gold anodized finish with threaded screw
GDT internal hex Click Attachment, 3mm collar height, gold anodized finish with threaded screw
GDT internal hex Click Attachment, 4mm collar height, gold anodized finish with threaded screw
GDT internal hex Click Attachment, 5mm collar height, gold anodized finish with threaded screw
GDT internal hex Click Attachment, 6mm collar height, gold anodized finish with threaded screw
CODE
LOC1
LOC2
LOC3
LOC4
LOC5
LOC6
PLATFORMØ3.8
DIAMETERØ3.8
CONNECTIONInternal Hexagon 2.42mm
https://gdentalt.com/wp-content/uploads/2025/04/Standard-Platform-Internal-Hex-2.42mm-sign-with-dimensions.svg

Angulated 18˚ Click Attachments

LENGTH
0.5mm
1mm
2mm
3mm
 
GDT internal hex 18 degree Angulated Click Attachment, 0.5mm collar height, gold anodized finish.
GDT internal hex 18-degree Angulated Click Attachment, 1mm collar height, gold anodized finish.
GDT internal hex 18-degree Angulated Click Attachment, 2mm collar height, gold anodized finish.
GDT internal hex 18-degree Angulated Click Attachment, 2mm collar height, gold anodized finish.
CODE
LOC-1805
LOC-1810
LOC-1820
LOC-1830
PLATFORMØ3.8
DIAMETERØ5.2
CONNECTIONInternal Hexagon 2.42mm
https://gdentalt.com/wp-content/uploads/2025/04/Standard-Platform-Internal-Hex-2.42mm-sign-with-dimensions.svg

Angulated 30˚ Click Attachments

LENGTH
0.5mm
1mm
2mm
3mm
 
GDT internal hex 30-degree Angulated Click Attachment, 0.5mm collar height, gold anodized finish.
GDT internal hex 30-degree Angulated Click Attachment, 1mm collar height, gold anodized finish.
GDT internal hex 30-degree Angulated Click Attachment, 2mm collar height, gold anodized finish.
GDT internal hex 30-degree Angulated Click Attachment, 3mm collar height, gold anodized finish.
CODE
LOC-3005
LOC-3010
LOC-3020
LOC-3030
PLATFORMØ3.8
DIAMETERØ5.2
CONNECTIONInternal Hexagon 2.42mm
https://gdentalt.com/wp-content/uploads/2025/04/Slim-Platform-Internal-Hex-2.0mm-sign-with-dimensions.svg

Slim Straight Click Attachments

LENGTH
1mm
2mm
3mm
4mm
 
GDT Slim Click Attachment, 1mm collar height, gold anodized finish with threaded screw
GDT Slim Click Attachment, 2mm collar height, gold anodized finish with threaded screw
GDT Slim Click Attachment, 3mm collar height, gold anodized finish with threaded screw
GDT Slim Click Attachment, 4mm collar height, gold anodized finish with threaded screw
CODE
LOC1-SL
LOC2-SL
LOC3-SL
LOC4-SL
PLATFORMØ3.0
DIAMETERØ3.5
CONNECTIONSlim Internal Hexagon 2.0mm
Click Attachment Components
Extra Soft Silicone Cap
(0.6 kg / 1.3 lbs)
GDT Click Attachment yellow extra soft silicone cap insert
SYCL
Soft Silicone Cap
(1.2 kg / 2.6 lbs)
GDT Click Attachment pink soft silicone cap insert, isolated product image.
SPCL
Standard Silicone Cap
(1.8 kg / 4 lbs)
GDT Click Attachment clear standard silicone cap insert
SWCL
Strong Silicone Cap
(2.7 kg / 6 lbs)
GDT Click Attachment violet strong silicone cap insert
STCL
Lab Silicone Cap
GDT Click Attachment black lab silicone cap insert.
SBCL
Protective Disc
GDT Click Attachment protective disc
DP
Titanium Housing
GDT Click Attachment metal housing in titanium finish
MTCL
Analog
GDT Click Attachment Analog, shown on a white background.
AFL
Impression Coping
GDT Click Attachment transfer impression coping
TFL
Insertion and Extraction Driver
GDT driver for insertion and extration of Click Attachment silicone caps
HLC

Media

FAQs

How do GDT Click Attachments simplify maintenance for dentists and patients?

How much dental implant divergence can GDT Angulated Click Attachments correct?

How does the GDT silicone cap system allow for customized overdenture retention?

Ask anything about
Click Attachment