A close-up view of a GDT dental implant analog with conical connection for accurate positioning in a cast model.

Conical Analogs

A close-up view of a GDT dental implant analog with conical connection for accurate positioning in a cast model.

GDT Conical Implant Analogs are designed to replicate implant position in the working model with high accuracy, supporting predictable restorative outcomes and reducing chairside adjustments. Built for reliable transfer from the clinical impression to the lab, they help ensure the final prosthesis aligns with the implant’s true orientation. The range includes standard and digital scan analog options to support both conventional and CAD/CAM workflows for precise, stable restorations.

  • Connections
    • Narrow Platform (NP) 2.25mm
      Narrow Platform (NP) 2.25mm
    • Regular Platform (RP) 2.65mm
      Regular Platform (RP) 2.65mm
  • Material
    Stainless Steel

GDT Conical Implant Analogs provide a critical solution for replicating the precise position of dental implants after an impression has been taken, ensuring that all subsequent restorative procedures align perfectly with the clinical reality. Using the cast model or digital implant analogs Dental professionals can confidently finalize abutment placement and prosthetic design. Reduces chairside adjustments, and contributes to improved long-term treatment outcomes.

Precision Engineering for Reliable Clinical Results

Manufactured from medical-grade stainless steel, GDT Conical Implant Analogs are engineered for precision and durability. Their robust construction ensures the accurate transfer of implant positions from the patient’s mouth to a working model, enabling dental professionals to replicate the implant’s exact positioning within the cast. This results in a highly accurate prosthesis design that supports long-term functionality and provides exceptional esthetics.

By using GDT Conical Implant Analogs, dental professionals gain the confidence to design and fabricate prostheses that fit seamlessly, minimizing the need for adjustments. The precision of these analogs facilitates a streamlined restorative process, ensuring that each case is executed with clarity and certainty, improving both the patient’s outcome and the clinician’s efficiency.

Compatibility Across Platforms and Systems

GDT Conical Implant Analogs are compatible with leading implant systems, including NobelActive® conical connection, making them a versatile choice for various clinical needs. They are available in two platform sizes: Narrow Platform (NP) 3.5mm and Regular Platform (RP) 4.3-5.0mm, offering flexibility in implant restoration.

The availability of both platform sizes ensures that these analogs are compatible to different implant systems and restorative requirements.

Digital Advancements with CAD/CAM Integration

As the dental industry increasingly adopts digital technologies, GDT Conical CAD/CAM Digital Scan Analogs offer significant advantages over traditional analogs. These digital analogs enable the creation of highly accurate 3D models, providing a modern solution for implant restorations. By scanning the placed implant, dental professionals can digitally replicate the implant’s position and use our Conical Digital Analog as a direct replica for further design and fabrication.

The GDT Conical Digital Analogs are especially beneficial for restorations that require high precision, including full denture cases. Each analog is designed with fixation screws to ensure secure attachment to the model, preventing movement during the restorative process. This stability is crucial for maintaining the accuracy of the final restoration.

Maximizing Accuracy and Reliability in Restorative Dentistry

The high level of accuracy provided by GDT Conical Implant Analogs is crucial in determining the precise location, orientation, and angle of implants, ensuring that the prosthetic design will align perfectly with the clinical outcome. The combination of digital scanning capabilities and analog precision allows dental professionals to achieve optimal results.

GDT Conical Implant Analogs and Digital Scan Analogs provide the reliability needed for complex implant placements, enabling more efficient treatment planning and greater patient satisfaction. By using these solutions, dental professionals can confidently address challenging restorative cases.

Supporting Long-Term Treatment Success

With GDT Conical Implant Analogs, dental professionals gain access to a high-precision tool that supports the longevity and stability of dental implant restoration. The analogs ensure that the implant position is accurately transferred to the model, eliminating errors and improving the precision of the prosthetic. This results in improved load distribution, better soft tissue integration, and a longer-lasting prosthesis.

GDT Conical Analogs Sizes

TypeNPRP
StandardANGNPANGRP
DigitalANG3DNPANG3DRP
Implant Analogs

TypeMU 1.4MU 1.6
StandardNM-ANGMU-ANG
DigitalNM-ANG3DMU-ANG3D
Multi-Unit Analogs

TypeClick AttachmentBall AttachmentGdtLoc Attachment
CodeAFEAFBAFL
Overdenture Analogs
Implant Analog
Implant Analog
https://gdentalt.com/wp-content/uploads/2026/02/Conical-Narrow-Connection-NP-2.25mm-sign-with-dimensions.svg

Implant Analogs - Narrow Platform (NP)

TYPE
Standard
Digital
 
GDT conical connection NP analog, front view showing the lab analog body and connection geometry.
GDT conical connection NP digital analog for CAD CAM workflows, front view on white background.
CODE
ANGNP
ANG3DNP
DIAMETERØ3.5
CONNECTIONNarrow Platform (NP) 2.25mm
https://gdentalt.com/wp-content/uploads/2026/02/Conical-Regular-Connection-NP-2.65mm-sign-with-dimensions.svg

Implant Analogs - Regular Platform (RP)

TYPE
Standard
Digital
 
GDT conical connection RP analog, front view showing the lab analog body and connection geometry.
GDT conical connection RP digital analog for CAD CAM workflows, front view on white background.
CODE
ANGRP
ANG3DRP
DIAMETERØ3.9
CONNECTIONRegular Platform (RP) 2.65mm

Multi-Unit Analogs

TYPE
LENGTH
DIAMETER
Multi-Unit 1.4
18mm
Ø4.9
Multi-Unit 1.6
13.5mm
Ø4.8
 
GDT Screw-retained multi-unit 1.4 Analog
GDT Screw-retained multi-unit 1.6 Analog
CODE
NM-ANG
MU-ANG

Digital Multi-Unit Analogs

TYPE
LENGTH
DIAMETER
Multi-Unit 1.4
9mm
Ø4.9
Multi-Unit 1.6
12mm
Ø4.8
 
GDT Screw-retained multi-unit 1.4 Digital scan Analog
GDT Screw-retained multi-unit 1.6 Digital scan Analog
CODE
NM-ANG3D
MU-ANG3D

Overdenture Analogs

TYPE
LENGTH
DIAMETER
GdtLoc Attachment
14mm
Ø4.0
Ball Attachment
15mm
Ø3.8
Click Attachment
10.5mm
Ø3.8
 
GDT Overdenture GdtLoc Attachment Analog
GDT Overdenture ball Attachment dental Analog
GDT Overdenture click Attachment dental lab Analog
CODE
AFE
AFB
AFL

Media

FAQs

What are GDT Conical Implant Analogs used for?

What are the advantages of GDT Digital Scan Analogs?

What connection type are GDT Conical Analogs compatible with?

Ask anything about
Conical Analogs